SPECIFICATIONS
General Data Nominal Tonnage 7.5 Ton 8.5 Ton 10 Ton 12.5 Ton
Model Number KCC092S4M KCC102S4M KCC120S4M KCC150S4M
󰀩 Standard Standard Standard Standard
Blower Type MSAV
®
Multi-Stage
Air Volume
MSAV
®
Multi-Stage
Air Volume
MSAV
®
Multi-Stage
Air Volume
MSAV
®
Multi-Stage
Air Volume
Cooling
Performance
Gross Cooling Capacity - Btuh    
1
Net Cooling Capacity - Btuh    
 2400 2800 3200 3800
Total Unit Power - kW 7.7 8.7 10.3 12.6
1
 11.2 11.2 11.2 11.0
1
 14.8 14.8 14.8 14.2
Refrigerant
Charge
    
Environ™ Coil System Circuit 1    7 lbs. 0 oz.
Circuit 2 3 lbs. 12 oz. 3 lbs. 10 oz.  
 Circuit 1  10 lbs. 3 oz. 10 lbs. 0 oz. 12 lbs. 10 oz.
Circuit 2 6 lbs. 0 oz.  10 lbs. 8 oz. 12 lbs. 8 oz.


Circuit 1
 10 lbs. 12 oz.  13 lbs. 0 oz.
Circuit 2 6 lbs. 0 oz.  10 lbs. 8 oz. 12 lbs. 8 oz.
Electric Heat Available  
60 KW
Compressor Type (number) 
Outdoor Coils
Environ
(Fin/Tube)
   28.0 28.0
Number of rows    
    
Outdoor
Coil Fans
    
Motor rpm    
Total Motor watts 740 740  
    
Number of blades 3 3 3 3
Total Air volume - cfm 8800 8800  
Indoor
Coils
    
Tube diameter - in. 3/8 3/8 3/8 3/8
Number of rows 3 3 4 4
 14 14 14 14
Drain connection - Number and size 
Expansion device type Balanced Port Thermostatic Expansion Valve

2
Indoor
Blower and
Drive
Selection
Nominal motor output 
 
Motor - Drive kit number 2 hp
Kit 1
Kit 2
Kit 3
3 hp
Kit 4
Kit 5
Kit 6
5 hp
Kit 10
Kit 11
Kit 12
Blower wheel nominal diameter x width - in. 
Filters  
Number and size - in. 
Electrical characteristics 
NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction.
1

2
Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of

the service factor limitations outlined on the motor nameplate.
NOTE – Motor service factor limit - 1.0.