Appendix
8-15
L _^ONMObk
The following list shows the fault numbers which can be read under C1962:
Fault no. Meaning Classification
0 No fault
1 Invalid service designation Internal fault
2 Invalid call recognition Internal fault
3 Invalid data type Application error in the host
4 Invalid subcode number Application error in the host
5 Invalid code number Application error in the host
6 Invalid general parameter Application error in the host
7 Access error: operating status, e.g. controller inhibit Access error
8 Access erro r: because operating mode C0001 Access error
9 Access error: parameter only readable Access error
10 Access error: general Access error
11 Data block too long Limit value exceeded
12 Collision with other parameter values Limit value exceeded
13 Leave value range Limit value exceeded
14 General limit value exceeding Limit value exceeded
17 General internal fault Internal fault
32 General Communication f ault 2102IB <-> controller
33 Time limit exceeded Communication f ault 2102IB <-> controller
34 Frame error Communication f ault 2102IB <-> controller
35 Parity error Communication f ault 2102IB <-> controller
36 Overflow Communication f ault 2102IB <-> controller
37 Handshake Communication f ault 2102IB <-> controller
38 Block memory overflow Communication fault 2102IB <-> controller
208 Frame error Communication fa ult controller <-> 2102IB
209 Overflow error Communication f ault controller <-> 2102IB
210 Check-sum fault in the 2102IB fieldbus module detected Communication fault controller <-> 2102IB
211 Telegram interruption Communication fault controller <-> 2102IB
212 Invalid data Communication f ault controller <-> 2102IB
213 Invalid service Communication fa ult controller <-> 2102IB
214 Parity error Communication fa ult controller <-> 2102IB
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com