The LECOM-A/B protocol is used to exchange data between Lenze controllers and a host. The
LECOM-A/B protocol is based on DIN 66019, ISO 1745 and ANSI X3.28 (category 2.5 and A2, A4).
These standards are similar to each other and describe the control mode of a transmission section
of a transmission system.
The host, which is the master, can communicate with a slave (Lenze controller) in three modes:
• RECEIVE (see page 8-21)
• SEND (see page 8-23)
• BROADCAST/MULTICAST (see page 8-24)
8.3.1 General
The controllers communicate by means of the ASCII code:
0 1 2 3 4 5 6 7 8 9 O B C D I F
0 NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT jFF CR SO SI
1 DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
2 ÚÛ Ú>Û ÚÒÛ Ú@Û ÚAÛ ÚBÛ ÚCÛ ÚÛÛ ÚEÛ ÚFÛ ÚGÛ ÚHÛ ÚIÛ ÚJÛ ÚKÛ ÚLÛ
3 ÚMÛ ÚNÛ ÚOÛ ÚPÛ ÚQÛ ÚRÛ ÚSÛ ÚTÛ ÚUÛ ÚVÛ ÚWÛ ÚXÛ ÚYÛ ÚZÛ Ú[Û Ú\Û
4 Ú]Û Ú^Û Ú_Û Ú`Û ÚaÛ ÚbÛ ÚcÛ ÚdÛ ÚeÛ ÚfÛ ÚgÛ ÚhÛ ÚiÛ ÚjÛ ÚkÛ ÚlÛ
5 ÚmÛ ÚnÛ ÚoÛ ÚpÛ ÚqÛ ÚrÛ ÚsÛ ÚtÛ ÚuÛ ÚvÛ ÚwÛ ÚxÛ ÚyÛ ÚzÛ Ú{Û Ú|Û
6 ÚÚÛ Ú~Û ÚÄÛ ÚÅÛ ÚÇÛ ÚÉÛ ÚÑÛ ÚÖÛ ÚÜÛ ÚáÛ ÚàÛ ÚâÛ ÚäÛ ÚãÛ ÚåÛ ÚçÛ
7 ÚéÛ ÚèÛ ÚêÛ ÚëÛ ÚíÛ ÚìÛ ÚîÛ ÚïÛ ÚñÛ ÚóÛ ÚòÛ ÚôÛ ÚöÛ ÚõÛ ÚúÛ
Example:
”EOT” =02
hex
=2
dec
Character ”1” =31
hex
=49
dec
Code number (C1, C2)
Standard addressing
The meaning of the code numbers and the assigned parameters can be obtained from the code
table (see chapter 8.2). When transmitting data, the code number are coded as follows:
The following calculation determines the two ASCII digits from the code number (value range: 0 ¼
6229) (value range: 48
dec
¼ 127
dec
):
C1 = INTEGER((REMAINDER(code number/790))/10)+48
dec
C2 = REMAINDER(REMAINDER(code number/790)/10) +
INTEGER(code number/790) x 10 + 48
dec
The INTEGER is the digit before the decimal point, the REMAINDER is an integer.
Example: 13/5 = 2 remainder 3
INTEGER(13/5) = 2
REMAINDER(13/5) = 3
Example:
Convert code number 1002 in ASCII code C1 and C2:
C1
ASCII
= INTEGER((REMAINDER(1002/790))/10) + 48 =
INTEGER(212/10) + 48 =
21 + 48 = 69 = 45
hex
= ”E”
ASCII
C2
ASCII
= REMAINDER(REMAINDER(1002/790)/10) +
INTEGER(1002/790) x 10 + 48 =
REMAINDER(212/10) + 1 x 10 + 48 =
2+10+48=60=3C
hex
= ”<”
ASCII