Installation
UOMu_^MVMO 4-9
4.2.2.3 Connection diagram
L1
U
V
W
+UG
-UG
M
3~
PE
RB1 RB2
+UG
-UG
K10
K10
RB
L1
PE
8201... 8204
Z3
N
K10
-X1
N/L2
F1 F2*
PE
Z1
PE
PE
PE
PE
Z2
J
R
B
K10*
hPRKMNPR
F1 Fuse
F2* Fuse only for supply with 2AC / PE /
190-260V
K10 Mains contactor
K10* Mains contactor only for supply
with 2AC / PE / 190-260V
Z1 Mains filter/mains choke, see
Accessories
Z2 Motor filter/sine filter, see
Accessories
Z3 Brake chopper/brake module, see
Accessories
RB Brake resistor, see Accessories
J
RB
Temperature monitoring - brake
resistor
X1 Terminal strip in control cabinet
8204 operation only with assigned
mains choke/mains filter