Troubleshooting and fault elimination
820XBA1097 8-5
8.4 Reset of fault indications
TRIP
After eliminating the fault, the pulse inhibit will only be reset after the
acknowledgement of TRIP.
Note!
If the TRIP source is still active, the TRIP cannot be reset.
Code Name
Possible settings
IMPORTANT
Lenze Selection Info
C170
§
TRIP-reset
selection
-0- TRIP-reset by pressing the STP
key or a LOW signal at ctrl.
enable
-1- Auto-TRIPreset
C171 Deceleration for
Auto-TRIP reset
0 0{1s}60