Maintenance/repair
Repair
9
51
BA33.0001 EN 2.0
Procedure
1. Inhibit controller.
2. Disconnect power connection; in the case of terminal box design, disconnect power
supply between inverter and motor.
3. Measure the resistance between the following contacts or terminals:
Connector size 1.0; M23:
pins U
V, V
W, W
U
Connector size 1.5; M40:
pins 4
5, 5
6and6
4
–Terminalbox:
terminals 1
2,.2
3and3
1andU
V, V
W, W
U
4. The mean value calculated from the three measured values corresponds to twice the
phase resistance (star connection).
Use the mean value as R
1
and R
0
in the following e quation to calculate the
winding temperature
ϑ
1
:
Â
[
°
]
R
1
2
5
5
ϑ
1
Winding temperature during operation
Â
1
C] =
R
1
2
5
5
R
0
235
R
1
Winding resistance at operating temperature
R
0
R
0
Winding resistance at 20°C
9.3 Repair
ƒ
It is recommended to have all repairs performed by Lenze Service.
ƒ
Delivery of spare parts is available upon request.