Technical data
General data and operating conditions
4
Ò
22
EDSMDAG EN 2.0
4 Technical data
4.1 General data and operating conditions
Conformity and approval
Approval
ECE
R10 Rev. 5
ß 10R − 05 7105
(see nameplate)
MOBILE DCU
MOBILE PSU
MOBILE DCU PSU
ß 10R − 05 8467
(see nameplate)
MOBILE DCU S
Protection of persons and equipment
Degree of protection ISO 20653
IP 6K9K
l Plug mounted
l Cover sheet mounted
IP 6K7
l Plug mounted
l Without cover sheet
Insulation test EN 61800−5−1 Final test with 2.6kVDC between HV on−board supply
system/LV on−board supply system and HV on−board supply
system/PE
Insulation of control
circuits
EN 61800−5−1
IEC 60664−1
Safe isolation by double/reinforced insulation to the HV
on−board supply system
Short−circuit strength Motor connection: limited short−circuit strength, the inverter
is disabled, error acknowledgement is required
Control terminals: full short−circuit strength
Protective measures
against
l Short circuit
l Overvoltage
l Motor Connection Test
l Device overtemperature
l Motor overtemperature
(PTC or thermal contact, I
2
t monitoring)
Leakage current EN 61800−5−1 I
AC
>3.5 mA
I
DC
>10 mA
Observe regulations and safety
instructions!
On/off switching MOBILE devices are suitable for frequent on/off switching,
e.g. in the setting−up operation.