94
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters
y
Baud rate: 9600 bps (UART)
y
Data length: 8 bits
y
Parity : None
y
Stop bit: 1 bit
y
Communication code: ASCII code
y
Use a crossed (reverse) cable.
Command reference list
COMMAND1 COMMAND2
DATA
(Hexadecimal)
COMMAND1 COMMAND2
DATA
(Hexadecimal)
01. Power k a 00 - 01 14. Treble k r 00 - 64
02. Input Select x b (See p.96) 15. Bass k s 00 - 64
03. Aspect
Ratio
k c (See p.96) 16. Balance k t 00 - 64
04. Screen
Mute
k d 00 - 01 17. 3D x t (See p.97)
05. Volume
Mute
k e 00 - 01
18. Color
Temperature
x u 00 - 64
06. Volume
Control
k f 00 - 64
19. Extended
3D
x v (See p.97)
07. Contrast k g 00 - 64
20. ISM
Method (
Plasma
)
j p (See p.98)
08. Brightness k h 00 - 64
21. Energy
Saving
j q (See p.98)
09. Color k i 00 - 64
22. Auto
Configuration
j u (See p.98)
10. Tint k j 00 - 64
24. Channel
Add/Del
m b 00 - 01
11. Sharpness k k 00 - 64 25. Key m c (See p.98)
12. OSD Select k l 00 - 01
26. Backlight
(
LCD
)
m g 00 - 64
13. Remote
Control
Lock Mode
k m 00 - 01
COMMAND1 COMMAND2
DATA00
(Hexadecimal)
DATA01
(Hexadecimal)
DATA02
(Hexadecimal)
DATA03
(Hexadecimal)
DATA04
(Hexadecimal)
DATA05
(Hexadecimal)
23. Channel
Tuning
ma
physical
program
high
major
program
low
major low minor high minor low attribute