LG DLEX4000 Ultra Large Front Load Electric Dryer-Inlet Hose5
NOTE
If any leaks are found, shut off the water faucet, remove the hose, and check the condition of the rubber seal.
Connecting Gas Dryers
WARNING
To reduce the risk of fire or explosion, electric shock, property damage, injury to persons, or death when
using this appliance, follow requirements including the following:
Electrical Requirements for Gas Models Only
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
For personal safety, this dryer must be properly grounded.
This dryer must be plugged into a 120-VAC, 60-Hz. grounded outlet protected by a 15-ampere fuse or circuit
breaker.
Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet.
ELECTRIC SHOCK HAZARD
Failure to follow safety warnings could result in serious injury
This dryer is equipped with a three-prong grounding plug for protection against shock hazards and should be
plugged directly into a
properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
Gas Supply Requirements
As shipped from the factory, this dryer is configured for use with natural gas (NG). It can be converted for use
with propane (LP) gas.
Gas pressure must not exceed 8-inch (20.4 cm) water column for NG, or 13-inch (33.1 cm) water column for LP.
A qualified service or gas company technician must connect the dryer to the gas service.
Isolate the dryer from the gas supply system by closing its individual manual shutoff valve during any pressure
testing of the gas supply.
DO NOT attempt any disassembly of the dryer; disassembly requires the attention and tools of an authorized
and qualified service technician or company.
Securely tighten all gas connections.
Connect the dryer to the type of gas shown on the nameplate.
WARNING
Gas Supply Requirements (continued)
Supply line requirements: Your laundry room must have a rigid gas supply line to your dryer. In the United
States, an individual manual shutoff valve MUST be installed within at least 6 ft. (1.8 m) of the dryer, in