Description Steam Dryer
Electrical requirements Please refer to the rating label regarding detailed information.
Gas requirements NG 4-10.5 inches WC
LP: 8–13 inches WC (Gas Models only)
Max. water pressure 21.8 ~ 116 psi (150 ~ 800 kPa)
Dimensions 27” (W) X 28
15
/
16
(D) X 40
3
/
16
(H), 50
1
/
4
(D with door open)
68.6 cm (W) X 73.4 cm (D) X 102 cm (H), 127.5 cm (D with door open)
Net weight Gas dryer : 137.6 lbs (62.4 kg)
Electric dryer : 134.5 lbs (61 kg)
Drying capacity
- Normal cycle IEC 7.3 cu.ft. (22.5 lb/10.2 kg)
SPECIFICATIONS
Before Calling for Service (cont.)
 

There are no
creases left on
garment after
Steam Fresh™
The function of this cycle is to
remove wrinkles from fabric.
• Use an iron to make creases.
Odors remain
in clothing after
Steam Fresh™
Steam Fresh™ did not remove
odor completely.
Fabrics containing strong odors should be washed in a
normal cycle.
Flow Sense™
indicator
shows four
bars during the
drying cycle
Ductwork is too long or has too
many turns/restrictions.
Significant blockage of the
ductwork due to lint buildup or
debris.
The appliance has detected a
restriction in the external dryer
venting.
Install a shorter or straighter duct run. See the Installation
Instructions.
Ductwork should be checked/cleaned soon.
Dryer can be used in this condition, but drying times may
be longer.
If exhaust restrictions are sensed by the Flow Sense™
system, the indicator will remain on for two hours after
the end of the cycle. Opening the door or pressing the
POWER button will turn off the display.
The display
shows
d90”, d95”
The duct work is about 90%-95%
blocked.
(“d90” or d95” error code
displayed 2 hours only)
• House exhaust system blocked.
Do not use the dryer until the exhaust system has been
cleaned and/or repaired. Using the dryer with a severely
restricted exhaust is dangerous and could result in a fire
or other property damage.
Check the outside dryer vent while the dryer is operating
to make sure there is strong airflow.
If the exhaust system is extremely long, have it repaired or
rerouted.
• Keep the area around the dryer clean and free of clutter.
• Check vent hood for damage or lint clogging.
• Make sure the area around the vent hood is clear.
TROUBLESHOOTING / SPECIFICATIONS
MFL67731050_en_141213.indd 47 2014.12.13 5:22:36 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG DLEY1701*E and is the answer not in the manual?

LG DLEY1701*E Specifications

General IconGeneral
BrandLG
ModelDLEY1701*E
CategoryDryer
LanguageEnglish

Related product manuals