49
ERROR MODE / POWER FAIL RECOVERY / DEFAULT DRYER SETTINGS
PROBLEM POSSIBLE CAUSE SOLUTION
It is displayed when thermistor is opened or
shorted
Thermistor should be replaced.
It is displayed when thermistor temperature
have increased about 17 degrees for 10
seconds
Thermistor should be replaced.
Disconnection of card reader wire. Check the card reader wire.
ERROR MODE
■ Meaning of Error Codes that LED displays during occurrence or
problem.
Dryer error code
POWER FAIL RECOVERY
In case of power failure the machine stops running but the time display remains on, showing the time just before
power failure.
Press the Start button after the power is restored, then the machine will restart.
DEFAULT DRYER SETTINGS
Default Settings Default
Cycle Time (Minutes) 50 Minutes
Cool Down Time Cycle 2 Minutes
High Temperature 154,4° F (68° C)
Medium Temperature 140° F (60° C)
Low Temperature 125,6° F (52,5° C)
Top O Time (Minutes per coin) 10 Minutes
Coin #1 Value 0.1
Coin #2 Value 0.1
Minutes/Minutes and seconds Minutes
Fahrenheit/Celsius Fahrenheit
Error Mode On
MFL62512875_150414.indd 49 2015.4.14 9:44:26 AM