3.1.2 Automatic reclosure
Automatic reclosure is activated after a preset PAUSE TIME.
In this mode, by pressing the ‘STEP’ key, the automation changes its motion according to the sequence 1 – OPEN 2 – PAUSE 3 – CLOSE 4 - PAUSE;
for example, if the automation is opening and one selects the step command on the remote control, the automation stops in pause; conversely, if the
automation is closed, when the step command is given it opens. PAUSE TIME is intended as the pause time before automatic re-closure.
Press
and to set the various PAUSE TIME values.
Wait 25 seconds or press
again to quit.
OPEN » PAUSE » CLOSE » PAUSE
Press the green LED (RIGHT) switches on
:
• i
f none of the LEDs is switched on, automatic
reclosure is not enabled, to enable it press ;
• i
f at least one of the LEDs is switched on,
a
utomatic reclosure is enabled, to deactivate it press
until all the LEDs switch off.
LEDS ON PAUSE TIME
AUTOMATIC RE-CLOSURE IS NOT ENABLED
5 s
10 s
30 s
60 s
120 s
3.1.3 OPTION MENU 1
Press to enter OPTION menu, press repeatedly to select further options, the flashing led shows the position, by pressing button +
the function is activated (red led on), by pressing button– the function is desactivated.
LEDS ON
OPTIONS 1
NO FUNCTIONS ACTIVATED
Block of appartment: Step-by-step in opening
Modifies the function in: OPENING-STOP-CLOSING-STOP
Automatic 2 Steps: OPENING - CLOSURE
Input Stop becomes PHOTO2, the photocells intervenes
in opening with brief invertion.
CLOSING PASSING BY: passing by the photocells
(PHOTO), the automation closes after 5”.
5”
LEDS
Preflashing
Soft Start
OPTIONS 2
OPTION MENU 2
Press the option button (bottom right) for 5 seconds, then press in sequence to scroll through the options as shown byPress the option button for 5 seconds, then press in sequence to scroll through the options as shown by
the five led’s at the top. The flashing of the led indicates the option selected. The + button is used to select the functionthe fi ve led’s at the top. The fl ashing of the led indicates the option selected. The + button is used to select the function
indicated by the led staying lit. The – button will de select the option. To exit continue to scroll through to option 5.indicated by the led staying lit. The – button will de select the option. To exit continue to scroll through to option 5.
5 Secs
Lightning in pause
NO FUNCTIONS ACTIVATED
* Electronic heater
* By activating the heater, the entry becomes entry PHOTO1 THERMOSTAT.
When the contact is closed, the heater is on, in the opposite with the contact open the heater is turned off.
OPTION MENU 2
5
Exclusion of decelerationExclusion of deceleration