Status led’s - 2 led’s, 1 green and 1 red, are provided to indicate current controller status and faults.
Motor direction switches - Used to change direction of motors, 2 are provided, 1 for each motor.
Mode button - Places controller in manual mode, for jogging individual motors. Places controller
in calibration mode, where stall current can be increased or decreased or returns controller to auto
mode.
Power source - 12 volt dc input. Unit will operate from 8 volts dc to 18 volts dc.
Motor 1 connector - Power and encoder input for motor 1.
Direction switch connector - Provides input from customer supplied extend and retract switch.
Stall calibration - Allows for adjustment of stall force.
Motor 2 connector - Power and encoder input for motor 2.
1-6 Manual mode -Jog
Press mode button 2 times quickly, press a 3
rd
time and hold for approximately 5 seconds. The green
ledwillashonandoff.Manualmodenowactiveformotor#1.Usingtheextendandretractswitch,
motor 1 can be jogged manually.
Pressthemodebutton1moretimeandthegreenledwillashonandoff.Manualmodeisnow
switchedtomotor#2.Theextendandretractswitchwillnowjogmotor#2.
When both motors have been jogged to the desired position, exit manual mode by pressing and
holdingthemodebuttonuntilbothredandgreenled’sstarttoash.Thecontrolisnowbackinauto
mode.
1-6. 2 Units with the C1 board “electronic” manual override.
In the event of any fault code,theunitcanbemanuallyoverriddenelectronicallyusingthesesteps:
1. Locate the circuit board
2. Press the “mode button” six times quickly, press a 7th time and hold for approximately 5
seconds.
3.TheredandgreenLEDlightswillbegintoashindicatingyouareinoverridemode
4. Using the wall switch, press and hold the “in” button until the unit comes completely in.
status led’s
motor direction
switches mode button
power connection
motor 1 connector motor 2 connector
direction switch
stall calibration
4

Other manuals for Lippert Components 13398-C2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lippert Components 13398-C2 and is the answer not in the manual?

Lippert Components 13398-C2 Specifications

General IconGeneral
BrandLippert Components
Model13398-C2
CategoryController
LanguageEnglish

Related product manuals