*) After modification of parameters marked with *, the
next operation cannot be performed until the controller has
been reset.
PROMPT: Record is not made because of the
under-voltage fault of input voltage when the sun
irradiation is too low.
PR 16
setting for float switch 2
(white cable, yellow wire, S-7)
0 to 9
0 no float switch (sensor deactivated)
0
6 float switch normally closed
7 float switch normally open
8 float switch normally open (for dual switch mode with float switch 1)
9 float switch normally closed (for dual switch mode with float switch 1)
others Do not set other values, it may cause the inverter to work abnormally
For “Dual switch mode”, both float switches must be set to value “8” or “9”
PR 17
setting for well probe 1
(black cable, red wire, S-6)
0 to 9
0 no well probe (sensor deactivated)
0
6 well probe normally closed
7 well probe normally open
8 well probe normally open (for dual switch mode with well probe 2)
9 well probe normally closed (for dual switch mode with well probe 2)
others Do not set other values, it may cause the inverter to work abnormally
For "Dual switch mode", both well probes must be set to value "8" or "9"
PR 18
setting for well probe 2
(black cable, yellow wire, S-5)
0 to 9
0 no well probe (sensor deactivated)
0
6 well probe normally closed
7 well probe normally open
8 well probe normally open (for dual switch mode with well probe 1)
9 well probe normally closed (for dual switch mode with well probe 1)
others Do not set other values, it may cause the inverter to work abnormally
For "Dual switch mode", both well probes must be set to value "8" or "9"
PR 19 total generated energy read-only 0
PR 20 to
PR 24
fault type record 1 to 5 read-only see chapter 4 the operating code explanation no
PR 25 rated motor power [kW] 0.1 to 300.00
When loss load protection is working the parameter must be set correctly, otherwise it may
cause to work abnormally.
according to
pump model
PR 26 number of pole pairs 1 to 10 Pole number is used to calculate the synchronous velocity. 1
PR 27
startup delay time after abnormal
water level of well probe 1 or 2
1 to 30,000
After the water level has been abnormal or idle load protection has been running, the controller
will restart after this period of time (in seconds). While countdown is still higher than 999
seconds, the displayed digits flicker, delay time displayed remains at 999.
600
PR 28 loss load protection 0 to 1
0 unavailable
0
1 available (delay time of idle load protection set at PR 27)
When idle load protection parameter is set to 1 and if the actual output frequency
is higher than the frequency set at PR 14, controller activate idle load protection.
PR 29
startup delay time after abnormal
water level of float switch 1 or 2
1 to 30,000
After the water level has been abnormal or idle load protection has been running, the controller
will restart after this period of time (in seconds). While countdown is still higher than 999
seconds, the displayed digits flicker, delay time displayed remains at 999
600