8
Socket Wires Connection
DC Power IN , positive (+) plug
NBZH PV-ZH202 compatible
one-strand, black
connect to positive pole (+) terminal
of the PV generator
DC Power IN , negative (–) plug
NBZH PV-ZH202 compatible
−
one-strand, black
connect to negative pole (–) terminal
of the PV generator
Motor Plug
four wires
yellow/green wire (M-1) connected to protective ground wire
red wire (M-2) connected to U phase of the motor
yellow wire (M-3) connected to V phase of the motor
blue wire (M-4) connected to W phase of the motor
Sensor Plug
white sensor cable
red wire (S-8)
For use with LORENTZ float switch: Connect to blue wire
of the float switch and set parameter “PR15” to value
“6”
yellow wire (S-7) float switch connection wire 2 (optional)
black wire (S-1)
Common ground for float switches
Connect to black wire of the LORENTZ float switch
black sensor cable
red wire (S-6)
For use with LORENTZ well probe sensor: Connect to the
white wire of the sensor and set parameter “PR17” to
value “6”
yellow wire (S-5) well probe connection wire 2 (optional)
black wire (S-1)
Common ground for well probe sensors
Connect blue wire of the LORENTZ well probe sensor
3.6 External Sockets