EasyManuals Logo
Home>Lufft>Accessories>V200A-UMB

Lufft V200A-UMB User Manual

Default Icon
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Operating Manual V25/09.2019
Ventus / Ventus-X / V200A
Chapter 20 Appendix 46
<ID> Device address (2 decimal places with leading zeros)
Response: $xxMWV,xxx.x,R,xxx.x,M,A*xx(CR)(LF)
$xxMWV, Message ID, xx is the device type ID, factory default: WI, i.e.
message ID $WIMWV (setting of the device type ID see page 25)
xxx.x Wind direction
,R, fix
xxx.x Wind speed
, fix
M Possible values K,N,M,S for km/h, Knots, m/s, mph
, fix
A A=valid value, V= invalid value
* Check sum identifier
xx Check sum as hex value
CR Carriage Return
LF Line Feed
Response in case of error
Request: <ID>‘TR4’(CR)
<ID> Device address (2 decimal places with leading zeros)
Response: $xxMWV,,R,,M,V*xx(CR)(LF)
$xxMWV, Message ID, see above
,R, fix
, fix
M Possible values K,N,M,S for km/h, Knots, m/s, mph
, fix
V V= invalid value
* Check sum identifier
xx Check sum as hex value
CR Carriage Return
LF Line Feed
Example:
Request: 01TR4
Response: $WIMWV,230.6,R,003.4,N,A*23
This means that the wind is coming at a speed of 3.4 knots from 230.6°

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lufft V200A-UMB and is the answer not in the manual?

Lufft V200A-UMB Specifications

General IconGeneral
BrandLufft
ModelV200A-UMB
CategoryAccessories
LanguageEnglish

Related product manuals