Operating Manual V25/09.2019
Ventus / Ventus-X / V200A
Chapter 20 Appendix 59
Example: C Request
0C!
000019<CR><LF> 18 Values available
0D0!
0+13.5+2.5+3.7+2.6<CR><LF>
Air temperature 13,5°C, curr.. wind speed 2,5m/s, max. Wind speed 3,7m/s, avg.wind speed 2,6m/s
0D1!
0+136.4+134.0+100.0+1010.4+1.160<CR><LF>
Curr. wind direction 136,4°, avg. wind direction(vct) 134,0°, Quality of wind measurement 100%, rel. air presssure (curr)
1010.4 hPa, air density 1.16kg/m³
0D2!
0+1.8+2.8+122.0+147.0<CR><LF>
Wind speed (min) 1,8m/s, Wind speed (vct)2,8m/s,Wind direction (min) 122,0°,Wind direction (max) 147,0°
0D3!
0+12.4+14.0+13.5<CR><LF>
Air temperature (min) 12,4°C, air temperature (max) 14,0°C, air temperature (avg) 13,5°C
0D4!
0+1008.2+1011.2+1009.1<CR><LF>
Rel. air pressure (min) 1008.2 hPa,rel. air pressure (max) 1011.7 hPa, rel. air pressure (avg) 1009.1 hPa
20.6.4.1 Buffer Assigment Base Data Set
Device configured for measurement values in metric units: