34 Part Number 000015432 Rev02 5/21
Detailed Descaling/Sanitizing Procedure
Ice machines that are heavily scaled or have not been
descaled on a regular basis will need to run the Heavily
Scaled Cleaning Procedure before this one. Failure to do
so may result in binding of the auger as the lime scale
releases from the auger and evaporator barrel.
Ice machine cleaner/descaler is used to remove lime scale
or other mineral deposits. Ice machine sanitizer is used to
remove algae or slime.
Step 1 Remove panels and set the ICE/OFF/CLEAN
toggle switch to the OFF position.
Step 2 Turn off the water supply to the ice machine.
Step 3 Remove all ice from the bin.
Step 4 Place ICE/OFF/CLEAN toggle switch in the
CLEAN position. The dump valve will open and drain the
water from the evaporator and reservoir.
Step 5 Wait approximately 30 seconds (or until the
evaporator is drained) and place the toggle switch in the
OFF position.
,
Caution
Use only Manitowoc approved Ice Machine Cleaner/
descaler part number 000000084. It is a violation
of Federal law to use these solutions in a manner
inconsistent with their labeling. Read and understand
all labels printed on bottles before use.