EasyManuals Logo
Home>Manitowoc>Ice Maker>Indigo ID1402A

Manitowoc Indigo ID1402A User Manual

Manitowoc Indigo ID1402A
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #225 background imageLoading...
Page #225 background image
Part Number STH025 11/16 225
Cycle Times/24-Hour Ice Production/
Refrigerant Pressure Charts
These charts are used as guidelines to verify correct ice
machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
Production and cycle times are for dice cube - Half
dice cube cycle times can be 2 - 3 minutes faster,
depending on model and ambient temperature.
Models ending in 6 (ie: ID0606A) are included in the
model series cycle times & pressures.
Regular cube production derate is 7%.
Ice production checks that are within 10% of the
chart are considered normal. This is due to variances
in water and air temperature. Actual temperatures
will seldom match the chart exactly.
Refer to “Symptom #2 - Operational Analysis Table”
page 125 for the list of data that must be collected for
refrigeration diagnostics.
Zero out manifold gauge set before obtaining
pressure readings to avoid misdiagnosis.
Discharge and suction pressure are highest at the
beginning of the cycle. Suction pressure will drop
throughout the cycle. Verify the pressures are within
the range indicated.
Record beginning of freeze cycle suction pressure
one minute after water pump energizes.
50Hz dice and half dice production derate is 12%.
50Hz regular cube total production derate is 14%.
Charts

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Indigo ID1402A and is the answer not in the manual?

Manitowoc Indigo ID1402A Specifications

General IconGeneral
BrandManitowoc
ModelIndigo ID1402A
CategoryIce Maker
LanguageEnglish

Related product manuals