74 Part Number STH025 11/16
LUMINICE® REMINDER
The LuminIce® growth inhibitor recirculates the air in the
ice machine foodzone over a UV bulb. This process will
inhibit the growth of common micro-organisms on all
exposed foodzone surfaces.
The Bulb Minder is a feature that displays a reminder to
change its bulb every 12 months.
1. From the Set-Up menu, use the Down arrow to
highlight LuminIce Minder.
2. Press the Checkmark. On this screen, you can choose
to turn the reminder to AUTO or OFF by highlighting
your choice and pressing the Checkmark. Selecting
one will deselect the other.
3. When the check reflects your preference, use the
Down arrow to navigate to Exit and press the
Checkmark. The display will return to the Set-Up
menu.