Q270 Condenser Fan Motor Replacement
Access to remove, clean or replace the condenser fan/
motor can be obtained by performing the following:
1. Disconnect electrical power to the ice machine at
the electrical service disconnect.
2. Remove the screws that secure the condenser to
the cabinet and the base to the cabinet.
3. Slide the base forward until contact is made with
the stop screw approximately 6 cm.
4. Remove right hand screw securing condenser to
base.
5. Pivot condenser forward to obtain 13 cm between
the cabinet and condenser shroud. Take care not
to kink refrigeration tubing.
Accessing the Condenser Fan Motor
!
Caution
Do not move base past the stop screw, tubing
damage could result.
REMOVE THREE
SCREWS AND
PULL BASE
FORWARD TO
STOP SCREW.
6 CM TO STOP
SCREW
REMOVE SCREW AND
PIVOT CONDENSER TO
OBTAIN 13 CM
CLEARANCE BETWEEN
CABINET AND
CONDENSER SHROUD.
13 CM
CLEARANCE
AFTER
PIVOTING
CONDENSER
PT1295A