Part Number 80-01111-9 7/10 165
1. Remove the back panel to access the bin
thermostat.
2. Disconnect both wires #12 and #1 from the bin
thermostat and check the resistance across the
bin thermostat terminals.
NOTE: After covering/uncovering the bulb holder with
ice, wait at least three minutes to allow the thermostat
to react. (Open/Close)
No Ice on Bulb Ice on Bulb Result
Closed (O) Open (OL) Thermostat good
Open (OL) Closed (O) Replace
thermostat