184 Part Number 80-1505-3 6/11
Cleaning the Ice Thickness Probe
Clean the ice thickness probe using the following
procedure.
1. Mix a solution of Manitowoc ice machine cleaner
and water (2 ounces of cleaner to 16 ounces of
water) in a container.
2. Soak ice thickness probe in container of cleaner/
water solution while disassembling and cleaning
water circuit components (soak ice thickness
probe for 10 minutes or longer).
3. Clean all ice thickness probe surfaces including
all plastic parts (do not use abrasives). Verify the
ice thickness probe cavity is clean. Thoroughly
rinse ice thickness probe (including cavity) with
clean water, then dry completely. Incomplete
rinsing and drying of the ice thickness probe
can cause premature harvest.
4. Reinstall ice thickness probe, then sanitize all ice
machine and bin/dispenser interior surfaces.