Procedure to Clean Heavily Scaled
Ice Machines
IB models and Ice machines that are heavily scaled or
have not been cleaned on a regular basis will need to
run this procedure.
GENERAL
Clean and sanitize the ice machine every six months
for efficient operation. If the ice machine requires more
frequent cleaning and sanitizing, consult a qualified
service company to test the water quality and
recommend appropriate water treatment. The ice
machine must be taken apart for cleaning and
sanitizing.
CLEANING PROCEDURE
!
Caution
Use only Manitowoc approved Ice Machine
Cleaner and Sanitizer for this application
(Manitowoc Cleaner part number 94-0546-3 and
Manitowoc Sanitizer part number 94-0565-3). It is
a violation of Federal law to use these solutions in
a manner inconsistent with their labeling. Read
and understand all labels printed on bottles
before use.
!
Caution
Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use
these solutions in a manner inconsistent with
their labeling.
!
Warning
Wear rubber gloves and safety goggles (and/or
face shield) when handling ice machine Cleaner
or Sanitizer.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc QuietQube SY0684C and is the answer not in the manual?

Manitowoc QuietQube SY0684C Specifications

General IconGeneral
BrandManitowoc
ModelQuietQube SY0684C
CategoryIce Maker
LanguageEnglish

Related product manuals