Part Number 80-1505-3 6/11 23
Installation
LOCATION OF ICE MACHINE
S600C/S680C/S850C/S1000C/S1200C/S1470C/
S1870C/S2070C/S2170C/S3070C
The location selected for the ice machine head section
must meet the following criteria. If any of these criteria
are not met, select another location.
• The location must be free of airborne and other
contaminants.
• The air temperature must be at least 35°F (1.7°C),
but must not exceed 110°F (43.4°C).
• The location must not be near heat-generating
equipment, in direct sunlight and be protected from
weather.
• The location must not obstruct airflow through or
around the ice machine. Refer to ice machine
head section clearance requirements.
IB0600C/IB0680C/IB0800C/IB1000C
• Ice/Beverage Ice Machines require the installation
of a thermostat to maintain dispenser ice level.
The thermostat ships with the ice machine.
• The ice machine head is installed with the
electrical inlet, water supply inlet, refrigeration
tubing and water drain entering from the back of
the ice machine.
• The ice machine head section contains a service
loop that must remain installed between the ice
machine head section and line set. Sufficient
tubing length must be available to allow 180°
rotation of the ice machine.
• Maintain a 3” space between the back of the ice
machine and the back of the dispenser to allow
room for the refrigeration line set service loop.
• The water inlet and electrical connection must
contain a service loop to allow future service and
maintenance access.
• The drain line must contain a union or other
suitable means of disconnection at the ice
machine head section.