EasyManuals Logo

Manitowoc RFF Series User Manual

Manitowoc RFF Series
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background image
Part Number 000015433_05 3/21 83
BIN THERMOSTAT
Model Setting Cut-Out Cut-In
UFF0200 / UNF0200
UNF0300 / UFF0350
5
37°F ±1
3°C ±.1
43°F ±1
6°C ±.1
RFF0320 / RNF0320
RFF0620 / RNF0620
RNF1100 / RNF1020C
RFF1300 / RFF1220C
RNF2000C / RFF2200C
RFF2500
3
35°F ±1
1.6°C ±.1
41°F ±1
5.0°C ±.1
LOW TEMPERATURE THERMOSTAT
EVAPORATOR SAFETY THERMOSTAT
Model Setting Cut-Out Cut-In
UFF0200 / UNF0300
5
-1°F ±1
-17.2°C ±.1
39°F ±1
4°C ±.1
UNF0200 / UNF0300
RNF0320
6
-3°F ±1
-19.5°C ±.1
39°F±.1
4°C ±.1
RFF0320 / UFF0350
7
-8°F ±.1
-22°C ±.1
39°F±.1
4°C ±.1
Component Specifications