Location of CVD Condensing Unit
The location selected for the CVD Condensing Unit must
meet the following criteria. If any of these criteria are not
met, select another location.
• The air temperature must be at least -20°F (-28.9°C)
but must not exceed 130°F (54.4°C).
• CVD675/CVD1185/CVD2085 Only - The air
temperature must be at least -20°F (-28.9°C) but
must not exceed 120°F (48.9°C).
• CVD1486 Only- The air temperature must be at least
50°F (10°C) but must not exceed 110°F (43°C).
• The location must not allow exhaust fan heat and/or
grease to enter the condenser.
• The location must not obstruct airflow through or
around the condensing unit. See below for clearance
requirements.
Condensing Unit Clearance Requirements
CVD675/CVD885/CVD1085/CVD1185/CVD2085
Top/Sides
There is no minimum clearance required, although 6”
(15.2 cm) is recommended for efficient operation and
servicing only.
Front/Back
48” (122 cm)
CVD1285/CVD1485/CVD1885
Top/Sides
There is no minimum clearance required, although 6”
(15.2 cm) is recommended for efficient operation and
servicing only.
Front
24” (61 cm)
Back
48” (122 cm)
CVD1486 ONLY
Top - 5” (12.7 cm) is required for efficient operation and
servicing.
Front/Back/Sides - 12” (30.5 cm)