Part Number 80-1479-3 7/10 193
S300A
All Self-Contained Air-cooled Models After Serial Number
110704351
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10 70/21 90/32
70/21 8.7-10.4 9.5-11.3 10.4-12.4
1-2.5
80/27 9.6-11.5 10.6-12.6 11.5-13.7
90/32 10.8-12.9 11.3-13.4 12.9-15.3
100/38 12.3-14.6 13.5-16.0 14.6-17.3
110/43 14.2-16.8 15.4-18.2 16.7-18.7
Air Temp. Entering
Condenser °F/°C
Water Temperature °F/°C
1
1 Based on average ice slab weight of 2.44 - 2.81 lb.
50/10 70/21 90/32
70/21 340 315 290
80/27 310 285 265
90/32 280 270 240
100/38 250 230 215
110/43 220 205 190
Air Temp
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
50/10 195-245 50-23 135-160 75-100
70/21 195-260 60-24 135-165 80-110
80/27 220-290 60-25 150-170 90-120
90/32 250-330 60-27 170-195 115-135
100/38 285-370 70-30 200-220 130-155
110/43 330-415 78-32 230-250 150-175