34 Part Number 80-1479-3 7/10
PARTS REMOVAL FOR CLEANING/SANITIZING
Single Evaporator Ice Machines
A. Remove the water curtain
Gently flex the curtain in the center and remove it
from the right side.
Slide the left pin out.
B. Remove the ice thickness probe
Compress the hinge pin on the top of the ice
thickness probe.
Pivot the ice thickness probe to disengage one pin
then the other. The ice thickness probe can be
cleaned at this point without complete removal. If
complete removal is desired, disconnect the ice
thickness control wiring from the control board.
C. Remove the water trough
Depress tabs on right and left side of the water
trough.
Allow front of water trough to drop as you pull
forward to disengage the rear pins.
NOTE: Proceed to page 37, Step 7.