–111–
UG050W SELF-CONTAINED WATER-COOLED
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle Harvest Cycle
Discharge Pressure Suction Pressure Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10 13.33-9.09 3.44-2.04 6.40-7.83 4.75-6.41
21 13.39-12.45 3.60-1.35 6.75-10.55 5.10-6.30
32 15.96-15.95 4.40-1.34 8.43-12.43 6.20-6.20
43 17.18-16.40 5.00-1.75 8.57-17.62 6.81-6.63