EasyManuals Logo
Home>Manitowoc>Ice Maker>UG040A

Manitowoc UG040A Technician's Handbook

Manitowoc UG040A
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
46
Analyzing Discharge Pressure
1. Determine the ice machine operating conditions:
Air temp. entering condenser ______
Air temp. around ice machine ______
Water temp. entering sump trough ______
2. Refer to Cycle Times/24 Hour Ice Production/
Refrigeration Pressure Chart for ice machine being
checked.
3. Use the operating conditions determined in Step 1
to find the published normal discharge pressures.
Freeze Cycle ______
Harvest Cycle ______
Perform an actual discharge pressure check.
Compare the actual discharge pressure (Step 3) with
the published discharge pressure (Step 2).
The discharge pressure is normal when the actual
pressure falls within the published pressure range for
the ice machine’s operating conditions. It is normal for
the discharge pressure to be higher at the beginning of
the freeze cycle (when load is greatest), then drop
throughout the freeze cycle.
Freeze Cycle
PSIG
Harvest Cycle
PSIG
Beginning
of Cycle
__________ __________
Middle
of Cycle
__________ __________
End
of Cycle
__________ __________

Table of Contents

Other manuals for Manitowoc UG040A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc UG040A and is the answer not in the manual?

Manitowoc UG040A Specifications

General IconGeneral
BrandManitowoc
ModelUG040A
CategoryIce Maker
LanguageEnglish

Related product manuals