►►8. DISPLAY ERRORS
See B Fig. 3
ERROR CAUSE SOLUTION
F0
OPERATION ERROR
1. The “ON/OFF” switch is turned
“ON” (|) when the generator is
plugged in
1. After disconnecting the generator,
see that the switch is in the “OFF” (0)
position, plug the generator in and turn
the switch “ON” (|)
F1
PHOTOCELL ERROR
1. No fuel
2. Fuel is contaminated
3. Photocell is dirty or damaged
4. Fuel lter is dirty
5. Ignition error
1. Turn the switch “OFF” (0), rell the fuel
tank
2. Turn the switch “OFF” (0) empty and
rell the fuel tank. Clean the lter using
clean fuel, do not damage the lter (SEE
PARA. 6)
3. Contact the technical service center
4. SEE PARA. 6
5. Contact the technical service center
F2
TEMPERATURE CONTROL SENSOR ERROR
1. Interrupted cable
2. Sensor is damaged
1. Contact the technical service center
2. Contact the technical service center
F3
THERMOSTAT ERROR
1. Internal generator overheating
2. Antitilting sensor intervent
1. Turn the generator off, wait until it is
cooled down
2. Place the heater on a level and stable
surface
LO
1. External temperature below 0°C 1. Normal condition
CH
1. Continuous operation 1. Normal condition
►►9. PREVENTIVE MAINTENANCE SCHEDULE
WARNING: BEFOR INITIATING ANY REPAIR OR MAINTENANCE PROCEDURE UNPLUG
THE FEEDER CABLE AND MAKE SURE THAT THE GENERATOR IS COOLED DOWN.
COMPONENT MAINTENANCE FREQUENCY MAINTENANCE PROCEDURE
Fuel tank Clean every 150-200 hours of
operation or when necessary
Empty and rinse with fresh fuel
Nozzle Clean or replace once per season or
when necessary
Contact the technical service center
Photocell Clean once per season or when
necessary
Contact the technical service center
Fuel lter Clean or replace twice per season or
when necessary
Clean the fuel lter with clean fuel
Ignition device Clean or replace every 1.000 hours
of operation, or when necessary
Contact the technical service center
Fan blades Clean when necessary Contact the technical service center
en
it
de
es
fr
nl
pt
da
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Master XL6 and is the answer not in the manual?

Master XL6 Specifications

General IconGeneral
BrandMaster
ModelXL6
CategoryHeater
LanguageEnglish

Related product manuals