42
CLEARANCE AND MAINTENANCE FOR ANTI-DUST KIT
Overview
Every inverter is already installed with anti-dusk kit from factory. This kit also keeps dusk from your inverter
and increases product reliability in harsh environment.
Clearance and Maintenance
Step 1: Please remove the screws on the sides of the inverter.
Step 2: Then, dustproof case can be removed and take out air filter foam as shown in below chart.
Step 3: Clean air filter foam and dustproof case. After clearance, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.