63
8.2 MCB LED INSTRUCTIONS
LED REFERENCE DESIGNATOR DESCRIPTION
RS485 DSP2
Indicates if the digital communication is working normally between the console and the MCB.
Blinking = Normal.
Off = Fault
MCU DSP1
Indicates if the console is working normally.
Blinking - Normal.
Light = MCU Fault.
Off = MCU No Power.
DOWN DSP5
Indicates if the console is commanding elevation down.
Light = Normal.
Off - No command from console received by the elevation motor.
UP DSP6
Indicates if the console is commanding elevation up.
Light = Normal.
Off = No command from console received by the elevation motor.
+12V DSP4
Indicates if the console voltage supply is present.
Light = Normal.
Off - 12 Volts are not provided by the MCB.