8. Specifications:
The MR16out is for use in low voltage, class 2 circuits only.
Primary power: 12 to 24Vdc ±10%, 1100mA maximum
12Vdc @ 850mA nominal
24Vdc @ 450mA nominal
Relay contacts: 16 Form-C, 5A @ 30Vdc, resistive
Inputs: 2 unsupervised, dedicated for cabinet tamper and UPS fault monitoring
Communication: RS-485, 2-wire. 9600, 19200, 38400, or 115200 bps
Cable requirements:
Power: 1 twisted pair, 18 AWG
RS-485: 24AWG, 120 ohm impedance, twisted pair with shield, 4,000' (1,200m)
maximum
Inputs: 1 twisted pair, 30 ohms maximum
Outputs: As required for the load
Mechanical:
Dimension: 6" (152mm)W x 8" (203mm)L x 1" (25.4mm)H
Weight: 14 oz. ( 400 gm) nominal
Environmental:
Temperature: -55°C to +85°C, storage
0°C, to +70°C, operating
Humidity: 0% to 95% RHNC
Warranty:
Mercury Security Corporation warrants the product is free from defects in material and workmanship under normal
use and service with proper maintenance for one year from the date of factory shipment. Mercury Security
Corporation assumes no responsibility for products damaged by improper handling or installation. This warranty is
limited to the repair or replacement of the defective unit.
There are no expressed warranties other than set forth herein. Mercury Security Corporation does not make, nor
intends, nor does it authorize any agent or representative to make any other warranties, or implied warranties, and
expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose.
Returned units are repaired or replaced from a stock of reconditioned units. Returns must be accompanied by a
return authorization number (RMA) obtained from customer service, and prepaid postage and insurance.
Liability:
The Interface should only be used to control exits from areas where an alternative method for exit is available. This
product is not intended for, nor is rated for operation in life-critical control applications. Mercury Security Corporation
is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or
malfunction of the product. Mercury Security Corporation's liability does not extend beyond the purchase price of the
product.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury Security MR16out and is the answer not in the manual?

Mercury Security MR16out Specifications

Power IconPower
primary power voltage range12 to 24 Vdc ±10%
primary power maximum current1100 mA
nominal current at 12 Vdc850 mA
nominal current at 24 Vdc450 mA
Relay Contacts IconRelay Contacts
relay contact type16 Form-C
relay contact rating5 A @ 30 Vdc
relay contact resistanceresistive
Operating Environment IconOperating Environment
storage temperature range-55°C to +85°C
operating temperature range0°C to +70°C
humidity range0% to 95% RHNC
Weight and Dimensions IconWeight and Dimensions
dimension width6 in (152 mm)
dimension length8 in (203 mm)
dimension height1 in (25.4 mm)
weight14 oz (400 gm) nominal