52
CD630
Operation Chart - D3.6L, D4.2L and D4.2L LD
STARTING
PROCEDURE
AFTER
STARTING
WHILE
UNDERWAY
STOPPING &
SHUT DOWN
Turn on and run engine
compartment bilge blow-
er, if so equipped, for five
minutes.
Observe all gauges and
warning lights to check
condition of engine. If not
normal, stop engine.
Frequently observe all
gauges and indicator
lights to monitor engine
condition.
Shift remote control lever
to neutral position.
Check for leaks - fuel, oil,
water, fluid, etc.
Check for fuel, oil, water,
fluid, and exhaust leaks,
etc.
Run engine at idle speed
several minutes to allow
the turbocharger and
engine to cool.
Check that mechanical
engine-stop lever is not
engaged.
Check shift and throttle
control operation.
Toggle STOP switch
“Down” and hold, until
engine completely
stops.
Prime fuel injection sys-
tem, if necessary.
Turn key switch to OFF
position.
Pre-lubricate turbochar-
ger and engine, if neces-
sary.
Turn battery switch OFF,
if so equipped.
Turn key switch to “RUN”
and check that lights and
indicator lamps come
on.
Flush seawater cooling
circuit, if operating in
saltwater area.
Check that charge indica-
tor and oil pressure indica-
tor lamps cease AFTER
engine starts.
Warm-up engine at idle
RPM for several minutes.
Open engine hatch. Air
out bilge completely.
Turn battery switch ON,
if so equipped.
Open seacock, if so
equipped.
Open fuel shut-off valve,
if so equipped.
Check steering opera-
tion.
Turn key switch to
START, after the indi-
cator lamp for glow
plugs (if so equipped)
ceases. Release key
when engine starts.
Close fuel shut-off valve,
if so equipped.
Close seacock, if so
equipped.