56
CD346
Operation Chart - D2.8L D-Tronic and D4.2L D-Tronic
STARTING
PROCEDURE
AFTER
STARTING
WHILE
UNDERWAY
STOPPING &
SHUT DOWN
Turn on and run engine
compartment bilge blow-
er, if so equipped, for five
minutes.
Observe all gauges and
warning lights to check
condition of engine. If
not normal, stop engine.
Frequently observe all
gauges and indicator
lights to monitor engine
condition.
Shift remote control le-
ver to neutral position.
Check for leaks - fuel,
oil, water, fluid, etc.
Check for fuel, oil, water,
fluid, and exhaust leaks,
etc.
Run engine at idle speed
several minutes to allow
the turbocharger and en-
gine to cool.
Check shift and throttle
control operation.
Prime fuel injection sys-
tem, if necessary.
Turn key switch to OFF
position.
Turn battery switch, if so
equipped, to OFF.
Turn key switch to RUN
and check that lights and
indicator lamps come
on.
Close seacock, if so
equipped.
Turn key switch to START,
after the indicator lamp for
glow plugs (if so equipped)
ceases. Release key
when engine starts.
Flush seawater cooling
circuit, if operating in salt-
water area.
Check that charge indica-
tor and oil pressure indi-
cator lamps cease AF-
TER engine starts.
Warm-up engine at idle
RPM for several minutes.
Open seacock, if so
equipped.
Open fuel shutoff valve,
if so equipped.
Open engine hatch. Air
out bilge completely.
Turn battery switch ON,
if so equipped.
Check steering opera-
tion.
Close fuel shutoff valve,
if so equipped.