Troubleshooting 6
4. Information Inquiry
To enter information inquiry status, complete the following procedure within ten seconds:
Press LED(or DO NOT DISTURB) 3 times.
Press SWING(or AIR DIRECTION) 3 times.
Finish 1 and 2 within 10 seconds, you will hear beeps for two seconds, which means the unit goes into parameter
checking mode.
Use the LED(or DO NOT DISTURB) and SWING(or AIR DIRECTION) buttons to cycle through information displayed.
Pressing LED(or DO NOT DISTURB) will display the next code in the sequence. Pressing SWING(or AIR DIRECTION) will
show the previous.
The following table shows information codes. The screen will display this code for two seconds, then the information
for 25 seconds.
Displayed code Explanation
Displayed
value
Meaning Additional Notes
T1
Room temperature
-14—70 -14—70
1. All displayed temperatures
use actual values.
2. All temperatures are
displayed in °C regardless
of remote used.
3. If the actual value exceeds
the range, it will display
the maximum value or
minimum value.
T2
Indoor coil
temperature
T3
Outdoor coil
temperature

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea AURORA ONOFF Series and is the answer not in the manual?

Midea AURORA ONOFF Series Specifications

General IconGeneral
BrandMidea
ModelAURORA ONOFF Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals