Service manual
- 31 -
Manual operation is controlled by touching buttons and divided into force cooling and forced auto
mode. It transfer between these two modes by pressing the buttons, the cycling order of the button
press is as below graph show to you.
10.12 Sleep mode
10.12.1 The sleep function is available at cooling, heating or auto mode
10.12.2 Cooling:
The set temperature rise 1 per hour. Two hours later, the set temperature will maintain as a
constant and the fan speed is kept at low speed.
10.12.3 Heating:
The set temperature decrease 1 per hour. Two hours later, the set temperature will maintain as a
constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
10.12.4 Auto:
After an hour running under economic mode, the set temp will rise 1,if it is under cooling mode; the
set temp will decrease 1,if it is under heating mode; the set temp will be changeless, if it is under
fan-only mode; the condition will be the same after the air conditioner running under economic mode
after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7
hours the unit stops.
10.13 Auto restart function