Service manual
- 35 -
12.2 Troubleshooting
For cooling mode:
Failure phenomenon
Operation
lam
p
Timer
lam
p
Indoor fan speed has been out of control for over 1 minute
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
On
Over current protection of the compressor occurs 4 times X
EEROM error On
No over-zero si
g
nal
☆☆
r
Extinguish
Flash at 5Hz
For heat pump mode:
Failure phenomenon
Operation
lam
p
Timer
lam
p
Defrostin
g
lam
p
Over current protection of the compressor occurs 4 times
X
Indoor fan speed has been out of control for over 1 minute X
☆☆
No over-zero si
g
nal
☆☆
Temp. sensor on indoor evaporator is open circuit or short circuit X X
Indoor room temp. sensor is open circuit or short circuit X
X
EEROM erro
r
On
X
r
Extinguish
Flash at 5Hz