9. Power connection options
Appropriate power cord accessory kit is determined by the voltage, and amperage of the branch circuit. The
unit does not come with a power cord (or hard wire kit). An accessory power cord must be ordered to
connect the unit to the outlet. If the unit is to be hard wired, an accessory hard wire kit must be ordered.
IMPORTANT:
For 265V units, if a power cord is selected, it must plug into the 265V subbase accessory.
Cord-connected Units
The 240V field supplied outlet must match the plug for the standard 208/230V units and be within reach of
the service cord. The standard cord-connected 265V units require an accessory electrical subbase for
operation.
Power Cord Protection
The power cord for230/208v units provide power cord fire protection. Unit power automatically disconnects
when unsafe conditions are detected. Power to the unit can be restored by pressing the reset button on
plug head. Upon completion of unit installation for 230/208V models, an operational check should be
performed using the TEST/RESET buttons on the plug head.
NOTE:
The 265V models do not incorporate this feature as they require use of the electrical subbase
accessory. Our sub base accessory is being developed
THE APPEARANCE OF POWER PLUG IS DIFFERNENT BECAUSE OF DIFFERENT SUPPLIER
www.mideaaircon.com
22

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MWDUP-15EEN1-MI5 and is the answer not in the manual?

Midea MWDUP-15EEN1-MI5 Specifications

General IconGeneral
BrandMidea
ModelMWDUP-15EEN1-MI5
CategoryAir Conditioner
LanguageEnglish

Related product manuals