EasyManuals Logo
Home>Midea>Air Conditioner>VRF V4 Plus I Series

Midea VRF V4 Plus I Series User Manual

Midea VRF V4 Plus I Series
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
R410A DC Inverter V4 Plus 50Hz MCAC-VTSM-2014-04
98 Troubleshooting
For example
Pressing the manual button continued for 10 seconds:
If all the LED lights turn off, that means the capacity code is 0 and the capacity of indoor units is
22×100W(0.8HP);
If the Timer and Alarm lights are normally on, that means the capacity code is 5=(41) and the
capacity of indoor unit is 7100W(2.5HP);
If the Operation and Alarm lights are normally on, that means the capacity code is 9=(8+1) and the
capacity of indoor unit is 140×100W(5.0HP);
If all the LED lights turn on, that means the capacity code is F=(8+4+2+1) and the capacity of indoor unit
is 160×100W(6.0HP).
The above basic principle just applies to single PCB, if the indoor unit has more than one PCB, or one PCB
can achieve a virtual multi blocks function, you must use the basic principle to calculate the achievable
capacity of single PCB at first, then add all the value as the capacity of the indoor unit .
For example
The high static pressure duct has capacity of 20kW, 25kW, 28kW and larger capacity of 40kW, 45kW, 56kW.
The Operation light is normally on, that means the capacity code is 8 and the achievable capacity of
single PCB is 112×100W(4.0HP), then add the value of two PCB, so the capacity of indoor unit is
200×100W(8.0HP);
The Operation and Alarm lights are normally on, that means the capacity code is 9=(8+1) and the
achievable capacity of single PCB is 140×100W(5.0HP), then add the value of two PCB, so the capacity
of indoor unit is 280×100W(10HP);
The Operation light is normally on, that means the capacity code is 8 and the achievable capacity of
single PCB is 112×100W(4.0HP), then add the value of four PCB, so the capacity of indoor unit is
450×100W(16HP);
The Operation and Alarm lights are normally on, that means the capacity code is 9=(8+1) and the
achievable capacity of single PCB is 140×100W(5.0HP), then add the value of four PCB, so the
capacity of indoor unit is 560×100W(20HP).
3. If the signal is weak, connect a 120Ω resistor between P and Q of the farthest indoor unit, or connect a
0.5-1.5uF capacitor between P and Q of outdoor unit. Installation refers to the following picture:
Note:
Signal wires should be shield wire and indoor units should be connected in series.
Indoor Unit
Outdoor Unit
Indoor Unit
Indoor Unit
Indoor Unit
R=120Ω
Capacitor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea VRF V4 Plus I Series and is the answer not in the manual?

Midea VRF V4 Plus I Series Specifications

General IconGeneral
BrandMidea
ModelVRF V4 Plus I Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals