Cleaning the drain pump and
non-return valve.
Use caution when cleaning the fil-
ters, non-return valve or drain
pump, as glass or bone splinters
may be caught in the bottom of the
wash cabinet.
If the water in the dishwasher is not
completely drained at the end of a pro-
gram, the drain pump or non-return
valve may be blocked. To clean them:
Remove the combination filter.
Use a jug or bowl to scoop the water
out of the wash cabinet.
Tilt the locking clamp to the side.
Pull out the non-return valve.
Rinse the non-return valve under run-
ning water.
The drain pump is situated under the
non-return valve (see arrow).
Before replacing the non-return valve,
check to make sure that nothing is ob-
structing the drain pump. Spin the im-
peller several times in both directions;
it should turn smoothly.
Carefully replace the non-return
valve and secure it with the locking
clamp.
Replace and secure the combination
filter.