Mounting
SXT designed to be mounted on the pole, the package includes a mounting bracket and steel clamp:
1. With the clip pointed forward, slide the
mounting bracket into the rail on the
bottom of the case, until the clip clicks into
place;
2. Guide the clamp through the opening in
the bracket;
3. Attach the unit to a pole, with the Ethernet
port pointing downward;
4. Use a PH2 screwdriver to tighten the rings
when alignment is complete;
5. Fix the Ethernet cable to the pole using zip
ties, less than one meter from the unit, to
avoid the cable being pulled out of the port;
6. Check mounting angle and positioning.
When mounting outdoors, please ensure that any
cable openings are directed downwards. Use POE
injector and proper grounding, this device has
specially designed grounding connector under the
port cover. Recommended using Cat6 cable. The
IP rating scale for this device is IP54.
The SXT device has a sliding door, behind which
the Ethernet ports and the reset buttons are
located. This door can be also secured shut with a
screw in the provided screw hole.
When using both Ethernet ports, make sure to cut
a wider cable opening in the plastic door. You can
use pliers to tear out the plastic piece that is
protecting the cable opening. When closing the
plastic door, make sure to apply pressure, until it
“clicks” into place.
Mounting and configuration of this device should be done by a qualified person.
Grounding
The installation infrastructure (towers and masts), as well as the router itself, must be properly grounded.
The device includes a grounding wire attachment connector behind the case door. Attach your grounding
wire to the grounding connector, then attach the other end of the grounding wire to the grounded mast.
This is to substantially reduce the risk of ESD and lightning damage.
See mikrotik.com/products for the latest version of this document. Page 2, Document # 49031 Modified on: 06.NOV.2019