EasyManuals Logo

Mitsubishi Electric MSZ-EF18VE User Manual

Mitsubishi Electric MSZ-EF18VE
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
En-9
Ɣ23(5$7,1*,16758&7,216Ɣ
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
7KHXQLWFDQQRWEHRSHUDWHG
 ,VWKHEUHDNHUWXUQHGRQ"
 ,VWKHSRZHUVXSSO\SOXJFRQQHFWHG"
 ,VWKH21WLPHUVHW"3DJH
7KHKRUL]RQWDOYDQHGRHVQRW
PRYH
 $UHWKH KRUL]RQWDOYDQHDQGWKHYHUWLFDOYDQH
LQVWDOOHGFRUUHFWO\"
 ,VWKHIDQJXDUGGHIRUPHG"
 :KHQWKHEUHDNHULVWXUQHGRQWKHKRUL]RQWDO
YDQHV¶SRVLWLRQZLOOEHUHVHWLQDERXWDPLQXWH
$IWHUWKHUHVHWKDVFRPSOHWHGWKHQRUPDOKRUL
]RQWDOYDQHV¶RSHUDWLRQUHVXPHV7KHVDPHLV
WUXHLQWKHHPHUJHQF\FRROLQJRSHUDWLRQ
7KHXQLWFDQQRWEHRSHUDWHG
IRUDERXWPLQXWHVZKHQ
UHVWDUWHG
This protects the unit according to instructions
IURPWKHPLFURSURFHVVRU3OHDVHZDLW
Mist is discharged from the air
RXWOHWRIWKHLQGRRUXQLW
7KHFRRODLUIURPWKHXQLWUDSLGO\FRROVPRLVWXUH
LQWKHDLULQVLGHWKHURRPDQGLWWXUQVLQWRPLVW
7KHVZLQJRSHUDWLRQRIWKH+25
,=217$/9$1(LVVXVSHQGHG
IRUDZKLOHWKHQUHVWDUWHG
 7KLVLVIRUWKHVZLQJRSHUDWLRQRIWKH+25,=21
7$/9$1(WREHSHUIRUPHGQRUPDOO\
:KHQ6:,1*LVVHOHFWHGLQ
&22/'5<)$1PRGHWKH
ORZHUKRUL]RQWDOYDQHGRHV
QRWPRYH
 ,WLV QRUPDOWKDWWKHORZHU KRUL]RQWDOYDQH
GRHVQRWPRYHZKHQ6:,1*LVVHOHFWHGLQ
&22/'5<)$1PRGH
7KHDLUÀRZGLUHFWLRQFKDQJHV
GXULQJRSHUDWLRQ
7KHGLUHFWLRQRIWKHKRUL]RQWDO
YDQHFDQQRWEHDGMXVWHGZLWK
WKHUHPRWHFRQWUROOHU
 :KHQ WKH XQLW LV RSHUDWHG LQ&22/ RU '5<
PRGHLIWKHRSHUDWLRQFRQWLQXHVZLWKDLUEORZLQJ
GRZQIRUWRKRXUWKHGLUHFWLRQRIWKHDLUÀRZ
LV DXWRPDWLFDOO\ VHW WR KRUL]RQWDO SRVLWLRQ WR
SUHYHQWZDWHUIURPFRQGHQVLQJDQGGULSSLQJ
 ,Q WKH KHDWLQJ RSHUDWLRQ LI WKH DLUÀRZ WHP
SHUDWXUHLVWRRORZRUZKHQGHIURVWLQJLVEHLQJ
GRQHWKHKRUL]RQWDOYDQHLVDXWRPDWLFDOO\VHW
WRKRUL]RQWDOSRVLWLRQ
7KHRSHUDWLRQVWRSVIRUDERXW
10 minutes in the heating
RSHUDWLRQ
 2XWGRRUXQLWLVLQGHIURVW
6LQFH WKLV LV FRPSOHWHG LQ PD[ PLQXWHV
SOHDVHZDLW:KHQWKHRXWVLGHWHPSHUDWXUHLVWRR
ORZDQGKXPLGLW\LVWRRKLJKIURVWLVIRUPHG
7KHXQLWVWDUWVRSHUDWLRQE\
LWVHOIZKHQWKHPDLQSRZHULV
WXUQHGRQEXWKDVQ¶WUHFHLYHG
VLJQIURPWKHUHPRWHFRQWURO
OHU
 7KHVH PRGHOV DUH HTXLSSHG ZLWK DQ DXWR
UHVWDUW IXQFWLRQ :KHQ WKH PDLQ SRZHU LV
WXUQHG RII ZLWKRXW VWRSSLQJ WKH XQLW ZLWK WKH
UHPRWHFRQWUROOHU DQG LVWXUQHGRQ DJDLQ WKH
XQLWVWDUWVRSHUDWLRQDXWRPDWLFDOO\LQWKHVDPH
PRGHDVWKHRQHVHWZLWKWKHUHPRWHFRQWURO
OHUMXVW EHIRUH WKHVKXWRII RI WKHPDLQSRZHU
5HIHUWR³$XWRUHVWDUWIXQFWLRQ´ page 4
7KHWZRKRUL]RQWDOYDQHV
WRXFKHDFKRWKHU7KHKRUL
]RQWDOYDQHVDUHLQDQDEQRU
PDOSRVLWLRQ7KHKRUL]RQWDO
vanes do not return to the
FRUUHFW³FORVHSRVLWLRQ´
3HUIRUPRQHRIWKHIROORZLQJ
7XUQRIIDQGRQWKHEUHDNHU0DNHVXUHWKHKRUL]RQ
WDOYDQHVPRYHWRWKHFRUUHFW³FORVHSRVLWLRQ´
 6WDUWDQGVWRSWKHHPHUJHQF\FRROLQJRSHUDWLRQ
DQGPDNHVXUHWKHKRUL]RQWDOYDQHVPRYHWRWKH
FRUUHFW³FORVHSRVLWLRQ´
,Q&22/'5<PRGHZKHQWKH
room temperature reaches near
the set temperature, the outdoor
unit stops, then the indoor unit
RSHUDWHVDWORZVSHHG
When the room temperature deviates from the
set temperature, the indoor fan starts running
DFFRUGLQJWRWKHVHWWLQJVRQWKHUHPRWHFRQWURO
OHU
Multi system
7KHLQGRRUXQLWZKLFKLVQRW
RSHUDWLQJEHFRPHVZDUPDQG
DVRXQGVLPLODUWRZDWHUÀRZ
LQJLVKHDUGIURPWKHXQLW
 $ VPDOO DPRXQW RI UHIULJHUDQW FRQWLQXHV WR
ÀRZLQWRWKHLQGRRUXQLWHYHQWKRXJKLWLVQRW
RSHUDWLQJ
When heating operation is
VHOHFWHGRSHUDWLRQGRHVQRW
VWDUWULJKWDZD\
When operation is started during defrosting of
RXWGRRUXQLWLVGRQHLWWDNHVDIHZPLQXWHVPD[
PLQXWHVWREORZRXWZDUPDLU
Outdoor Unit
The fan of the outdoor unit
does not rotate even though
WKHFRPSUHVVRULVUXQQLQJ
(YHQLIWKHIDQVWDUWVWRURWDWH
LWVWRSVVRRQ
 :KHQ WKH RXWVLGH WHPSHUDWXUH LV ORZGXULQJ
FRROLQJRSHUDWLRQWKHIDQRSHUDWHVLQWHUPLWWHQWO\
WRPDLQWDLQVXI¿FLHQWFRROLQJFDSDFLW\
:DWHUOHDNVIURPWKHRXWGRRU
XQLW
 'XULQJ&22/DQG'5<RSHUDWLRQVSLSHRUSLSH
FRQQHFWLQJVHFWLRQVDUHFRROHGDQGWKLVFDXVHV
ZDWHUWRFRQGHQVH
 ,QWKHKHDWLQJRSHUDWLRQZDWHUFRQGHQVHGRQ
WKHKHDWH[FKDQJHUGULSVGRZQ
In the heating operation, the defrosting operation
PDNHVLFHIRUPLQJRQWKHRXWGRRUXQLWPHOWDQG
GULSGRZQ
:KLWHVPRNHLVGLVFKDUJHG
IURPWKHRXWGRRUXQLW
 ,QWKHKHDWLQJRSHUDWLRQYDSRUJHQHUDWHGE\WKH
GHIURVWLQJRSHUDWLRQORRNVOLNHZKLWHVPRNH
Symptom Explanation & Check points
Remote controller
7KHGLVSOD\RQWKHUHPRWH
FRQWUROOHUGRHVQRWDSSHDU
RULWLVGLP7KHLQGRRUXQLW
does not respond to the
UHPRWHFRQWUROVLJQDO
 $UHWKHEDWWHULHVH[KDXVWHG"3DJH
 ,V WKH SRODULW\  RI WKH EDWWHULHV FRUUHFW"
3DJH
 $UHDQ\EXWWRQVRQWKHUHPRWHFRQWUROOHURIRWKHU
HOHFWULFDSSOLDQFHVEHLQJSUHVVHG"
Does not cool or heat
7KHURRPFDQQRWEHFRROHG
RUKHDWHGVXI¿FLHQWO\
 ,V WKH WHPSHUDWXUH VHWWLQJ DSSURSULDWH"
3DJH
 ,VWKHIDQVHWWLQJDSSURSULDWH"3OHDVHFKDQJH
IDQVSHHGWRKLJKHUVHWWLQJ3DJH
 $UHWKH¿OWHUVFOHDQ"3DJH
 ,VWKHIDQRUKHDWH[FKDQJHURIWKHLQGRRUXQLW
FOHDQ"3DJH
 $UHWKHUHDQ\REVWDFOHVEORFNLQJWKHDLULQOHWRU
RXWOHWRIWKHLQGRRURURXWGRRUXQLW"
 ,VDZLQGRZRUGRRURSHQ"
7KHURRPFDQQRWEHFRROHG
VXI¿FLHQWO\
 :KHQDYHQWLODWLRQIDQRUDJDVFRRNHULVXVHG
LQDURRPWKHFRROLQJORDGLQFUHDVHVUHVXOWLQJ
LQDQLQVXI¿FLHQWFRROLQJHIIHFW
 :KHQWKHRXWVLGHWHPSHUDWXUHLVKLJKWKHFRROLQJ
HIIHFWPD\QRWEHVXI¿FLHQW
7KHURRPFDQQRWEHKHDWHG
VXI¿FLHQWO\
 :KHQWKHRXWVLGHWHPSHUDWXUHLVORZWKHKHDWLQJ
HIIHFWPD\QRWEHVXI¿FLHQW
$LUGRHVQRWEORZRXWVRRQLQ
WKHKHDWLQJRSHUDWLRQ
 3OHDVHZDLWDVWKHXQLWLVSUHSDULQJWREORZRXW
ZDUPDLU
$LUÀRZ
The air from the indoor unit
VPHOOVVWUDQJH
 $UHWKH¿OWHUVFOHDQ"3DJH
 ,VWKHIDQRUKHDWH[FKDQJHURIWKHLQGRRUXQLW
FOHDQ"3DJH
 7KHXQLW PD\ VXFN LQDQ RGRU DGKHULQJ WR WKH
ZDOOFDUSHWIXUQLWXUHFORWKHWFDQGEORZLWRXW
ZLWKWKHDLU
Sound
&UDFNLQJVRXQGLVKHDUG
 7KLVVRXQGLVJHQHUDWHGE\WKHH[SDQVLRQFRQ
WUDFWLRQRIWKHIURQWSDQHOHWFGXHWRFKDQJHLQ
WHPSHUDWXUH
³%XUEOLQJ´VRXQGLVKHDUG
 7KLV VRXQG LV KHDUG ZKHQ WKH RXWVLGH DLU LV
DEVRUEHGIURPWKHGUDLQKRVHE\WXUQLQJRQWKH
UDQJHKRRGRUWKHYHQWLODWLRQIDQPDNLQJZDWHU
ÀRZLQJLQWKHGUDLQKRVHWRVSRXWRXW
7KLVVRXQGLVDOVRKHDUGZKHQWKHRXWVLGHDLU
EORZV LQWR WKHGUDLQ KRVH LQFDVH WKH RXWVLGH
ZLQGLVVWURQJ
0HFKDQLFDOVRXQGLVKHDUG
IURPWKHLQGRRUXQLW
 7KLVLVWKHVZLWFKLQJVRXQGLQWXUQLQJRQRIIWKH
IDQRUWKHFRPSUHVVRU
7KHVRXQGRIZDWHUÀRZLQJ
LVKHDUG
This is the sound of refrigerant or condensed
ZDWHUÀRZLQJLQWKHXQLW
+LVVLQJVRXQGLVVRPHWLPHV
KHDUG
 7KLVLV WKH VRXQG ZKHQ WKH ÀRZRI UHIULJHUDQW
LQVLGHWKHXQLWLVFKDQJHG
Timer
:HHNO\WLPHUGRHVQRWRSHU
DWHDFFRUGLQJWRVHWWLQJV
 ,VWKH212))WLPHUVHW"3DJH
 7UDQVPLWWKH VHWWLQJ LQIRUPDWLRQ RIWKH ZHHNO\
WLPHUWRWKHLQGRRUXQLWDJDLQ:KHQWKHLQIRU
PDWLRQLVVXFFHVVIXOO\UHFHLYHGDORQJEHHSZLOO
VRXQGIURPWKHLQGRRUXQLW,ILQIRUPDWLRQIDLOVWR
EHUHFHLYHGVKRUWEHHSVZLOOEHKHDUG(QVXUH
LQIRUPDWLRQLVVXFFHVVIXOO\UHFHLYHG3DJH
 :KHQDSRZHUIDLOXUHRFFXUVDQGWKHPDLQSRZHU
WXUQV RII WKHLQGRRUXQLW EXLOWLQ FORFN ZLOO EH
LQFRUUHFW$VDUHVXOWWKHZHHNO\WLPHUPD\QRW
ZRUNQRUPDOO\
%HVXUH WR SODFH WKHUHPRWH FRQWUROOHU ZKHUH
WKHVLJQDO FDQ EH UHFHLYHG E\ WKH LQGRRU XQLW
3DJH
The unit starts/stops the
RSHUDWLRQE\LWVHOI
 ,VWKHZHHNO\WLPHUVHW"3DJH
In the following cases, stop using the air conditioner and consult your dealer.
 :KHQZDWHUOHDNVRUGULSVIURPWKHLQGRRUXQLW
 :KHQWKHOHIWRSHUDWLRQLQGLFDWRUODPSEOLQNV
 :KHQWKHEUHDNHUWULSVIUHTXHQWO\
 7KHUHPRWHFRQWUROVLJQDOLVQRWUHFHLYHGLQDURRPZKHUHDQHOHFWURQLF212))
W\SHÀXRUHVFHQWODPSLQYHUWHUW\SHÀXRUHVFHQWODPSHWFLVXVHG
 2SHUDWLRQRIWKHDLUFRQGLWLRQHULQWHUIHUHVZLWKUDGLRRU79UHFHSWLRQ$QDPSOL
¿HUPD\EHUHTXLUHGIRUWKHDIIHFWHGGHYLFH
 :KHQDQDEQRUPDOVRXQGLVKHDUG
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
S G 79F509H02_en.indd 9 10/19/2010 3:41:45 PM

Other manuals for Mitsubishi Electric MSZ-EF18VE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MSZ-EF18VE and is the answer not in the manual?

Mitsubishi Electric MSZ-EF18VE Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMSZ-EF18VE
CategoryAir Conditioner
LanguageEnglish

Related product manuals