'19 • SCM-SM-276
-
156
-
RWC000Z331
3. ELECTRICAL WIRING
(1) Outdoor unit
Models SCM71ZS-W, 80ZS-W
BK RDBlack Red
BL WHBlue White
BR Brown Yellow
GN Green YG Yellow/Green
YE
EEV A,EEV B
L
Compressor motor
Electric expansion valve
Reactor
TH2(Tho-A)
TH3(Tho-D)
Heat exchanger temperature sensor 1
Outdoor air temperature sensor
Discharge pipe temperature sensor
CM
TH1(Tho-R1)
Connector
20S 4-way valve(coil)
Suction pipe temperature sensor
TH4(Tho-S)
Heat exchanger temperature sensor 2
TH5(Tho-R2)
FMo Fan motor
CN20V
CNSUB
CNFAN
CNA
CNC
CNEEV1
CNMAIN
CNTH
CN20S
EEV C,EEV D
TB1〜5 Terminal block
CNEEV2
CNB
CND
EEV
S-1
BK
WH
RD
V
W
U
FMo
R-1
CNTH
CNFAN
S-2
BK
WH
WH
S-1
CNSUB
CNMAIN
S
R
BK
WH
IN
IN
S
R
O
O
250V 20A
F4 FUSE
2 2 2
G2
YG
C-2
RD
C-1
CN20V
3
2
G1
YG
CNEEV1
CNEEV2
CNTH
TB2
CNA
CNB
CNC
CND
TB1
N
L
A
EEV
B
EEV
C
EEV
D
TB3
TB4
TB5
3
1
3
1
3
1
3
2/N
1
YG
WH
BK
BK
WH
RD
YG
BK
WH
BL
YG
BK
WH
YE
YG
BK
WH
BR
YG
UNIT A
UNIT B
UNIT C
UNIT D
M
3〜
M
M
M
M
M
YG
Power
supply
WH
RD BL
GN
PCB 2(SUB)
PCB 1(MAIN)
t゜
t゜
t゜
T2
T1
L
YE
YE
TH1 TH2 TH3
2
t゜
TH4
T12
T11
L
BL
BL
2/N
2/N
2/N
CN20S
20S
RD
2
(coil)
CM
To indoor unit
Power cable
Signal wire
Earth wire
1
3
T 1A L 250V
F3 FUSE
4444
3
SCM71ZS-W
Model name
2.5mm x 3 12 1.5mm x 420.0
2
2
[ ]
2
N
Power cable, indoor-outdoor connecting wires
Switchgear or circuit breaker capacity should be chosen according to national or regional electricity
The power cable specifications are based on the assumption that a metal or plastic conduit is used
with no more than three cables contained in a conduit and a voltage drop is 2%. For an installation
falling outside of these conditions, please follow the national or regional electricity regulations.
The wire numbers include earth wire(Yellow/Green)
*
regulations.
SCM80ZS-W
Color marks
Mark Color Mark Color
Meaning of marks
Item Description
Item Description
2
t゜
TH5
MAX running current Power cable
wire size x number*(A)
Power cable length
(m)
Connecting cable
wire size x number*
Power source
1 Phase
220-240V 50Hz
220V 60Hz