Page #164 background imageLoading...
Page #164 background image
'19 • SCM-SM-276
-
162
-
Notes 1. indicates wiring on site.
2. See the wiring diagram of outdoor unit about the line between
indoor unit and outdoor unit.
3. Use twin core cord0.3mm
2
at remote control line.
See spec sheet of remote control in case that the total length is more
than 100m.
4. Do not put remote control line alongside power source line.
5. Section 1(※1shows
electric circuit of motion sensorOption.
FMi1
RD
RD
1
2
CNI
BL
FS
CNZ
CNC
For HA
WH
RD
RD
Control PCB
RD
YE
YE
BK
BK
1
2
3
4
5
6
BK
BK
1
2
XR1
XR2
XR3
XR4
1
2
3
4
5
6
+12
SW2
SW6
SW5
SW7
LED2 LED3
X
Y
1
3
X
Y
TB2
WH
BK
WH8
9
10
11
12
CNW2
WH
CNW1
WH
CNB
WH
CNN
YE
CNH
BK
CNT
BL
Operation
Heating
Compressor ON
Inspection
Thc
Thi-R1
Thi-R2
Thi-R3
Thi-A
WH
WH
WH
WH
Remote control
WH
WH
WH
WH
WH
WH
WH
WH
5
6
7
2
3
4
1
CNR
WH
1
2
DM
M
RD
WH
+12
8
9
10
11
12
5
6
7
2
3
4
1
1
PIS
CNG
BL
CNV2
BK
2
4
3
1
3
Option
WH
BK
RD
WH
RD
BK
Prepare on site
M
1 4 5 6 7
RD
F3
2A
CNM1
WH
Power PCB
Power circuit
BL
or
BK
BR
or
WH
WH
or
BL
OR
or
YE
1
BL
3
1
WH
CNW3
WH
1
2
WH
RD
YEGN
3
5
CNW0
WH
1
3
YEGN
TB1
F13.15A
L
CNWR2
WH
BK
F23.15A
Earth
The line between
21
3
Power source line
Signal line
indoor unit and outdoor unit
1
2
CNTA
BL
Remote operation
input:volt-free contact
+12
Prepare on site
XR5Remote operation
input:volt-free contact
FMi1
FS Float switch
Indication lampRed-Inspection
Indication lampGreen-Normal operation
LED3
LED2
ConnectorCNB-Z
Model capacity settingSW6
Operation check,drain pump motor test runSW7-1
SW5
Temperature sensor Remote control
Temperature sensor Heat exchanger
Temperature sensor Return air
Thc
Thi-R1,2,3
Thi-A
TB2 Terminal blockSignal line)( mark
TB1 Terminal blockPower source)( mark
Remote control communication address
SW2
Plural units MasterSlave setting
L Reactor
F1-3 Fuse
Fan motor
Drain pump motorDM
Motion sensorPIS
Closed-end connectormark
BK Black
Blue
Color Marks
BL
Mark Color
BR Brown
OrangeOR
RedRD
WH
Yellow
White
YellowGreen
YE
YEGN
Item Description
Meaning of marks
(d)
 
Duct connected-Low / Middle static pressure type (FDUM)
 
Model FDUM50VH
PJG000Z488

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SCM71ZS-W and is the answer not in the manual?

Mitsubishi Heavy Industries SCM71ZS-W Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSCM71ZS-W
CategoryAir Conditioner
LanguageEnglish

Related product manuals