Self diagnosis function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of each function as follows:
Outdoor heat exchanger fluid pipe
sensor error
Outdoor temperature sensor error Broken outdoor sensor wire, poor connector connection
Description of trouble
Room temperature sensor error
Cause
Broken heat exchanger sensor wire, poor connector
connection
Indoor fan motor error
Heat exchanger sensor error
2 time flash
6 time flash
TIMER light ON
1 time flash
RUN light
2 time flash
1 time flash
TIMER light
RUN light keeps flashing
Broken room temperature sensor wire, poor connector connection
Defective fan motor, poor connector connection
Broken heat exchanger fluid pipe sensor wire, poor connector
connection
4 time flash Discharge pipe sensor error Broken discharge pipe sensor wire, poor connector connection.
When to contact your distributor without delay
Turn off the power switch immediately and inform your dealer in any of the following situations:
The fuse or switch blows continu-
ously.
The cable becomes extremely hot.
The covering of the cable is cracked.
The TV, radio or other equipment
starts to malfunction.
When faulty movement is observed when the ON/OFF but-
ton is pressed, even after turning off the power switch and
restarting the operation after 3 minutes, the faulty move-
ment does not disappear.
A switch does not activate properly. You hear a strange noise during opera-
tion.
3 minutes go
by, but, why ...
Fuse often blows.
The RUN and TIMER lights on the unit indication section
blink quickly (0.5 sec. ON; 0.5 sec. OFF) and don’t work.
CAUTION
If the power cord becomes damaged, ask your dealer or a qualified engineer to install the
replacement to avoid accidents.
RUN light ON
2 time flash
RUN light 2 time flash
Rotor lock
Defective compressor
Open phase on compressor
Defective outdoor unit boards
Gas shortage, defective discharge pipe sensor, closed service
valve
Broken power transistor, broken compressor wire
Broken discharge pipe sensor wire, poor connector connection
Compressor blockage
Compressor locking, open phase on compressor output,
shortcircuit on power transistor, closed service valve
Defective power supply, Broken signal wire, defective in/outdoor
unit boards
Power transistor error
4 time flash
Broken power transistor
Current cut
1 time flash
Trouble of outdoor unit
2 time flash
Over current
3 time flash
Overload operation, overcharge
Over heat of compressor
5 time flash
Error of signal transmission
6 time flash
Outdoor fan motor error
7 time flash
Defective fan motor, poor connector connection
RKX012A015_En.p65 5/22/06, 4:48 PM20
Black

Other manuals for Mitsubishi Heavy Industries SRK20ZG-S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SRK20ZG-S and is the answer not in the manual?

Mitsubishi Heavy Industries SRK20ZG-S Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSRK20ZG-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals