66
-
'18 • SRK-T-250
'09•SRK-DB-087D
(9)Air flow direction adjustment
(a) Flap
(b) Louver
(c) Swing
(i)
(ii)
(d)
Memory flap (Flap or louver stopped)
COOL, DRY, FAN
Wireless remote
control display
HEAT
Approx. 25°
Approx. 25°
Approx. 30°
Approx. 35°
Approx. 40°
Approx. 50° Approx. 70°
(Swing)
(Flap stopped)
Approx. 50°
Approx. 60°
Approx. 60°
Angle of flap from horizontal
Center installation
Wireless remote
control display
Right end installation
Left end installation
Angle of louver
Center
Left
approx. 30°
Right approx. 20°
Center
Right approx. 50°
Right approx. 20°
Right approx. 30°
Right approx. 45° Right approx. 50°
(Louver stopped)
(Swing) (Spot)(Wide)
In HEAT operationIn COOL, DRY, FAN operation
Approx. 35°
Approx. 70°
Approx.
25°
Approx. 60°
Air flow direction can be adjusted with by AIR FLOW (UP/DOWN) and (LEFT/RIGHT) button on the wireless
remote control.
Every time when you press the AIR FLOW
Every time when you press the AIR FLOW
Left approx. 50°
Left approx. 50°
Left approx. 20°
Left
approx. 20°
Left
approx. 45°
Center
'09•SRK-DB-087D
(10)
3D auto operation
(a)
(i)
(ii)
(b)
Cooling
Air flow selection
Operation mode
AUT
OH
I MED LO
Heating
Room temp. – Setting temp. >5°C
Room temp. – Setting temp.
5°C
Setting temp. – Room temp. >5°C Setting temp. – Room temp.
5°C
HIGH POWER AUTO
HI MED LO
HIGH POWER AUTO
<
=
<
=
Flap
Louver
Cooling
Up/down swing
Heating
Wide (Fixed)Center (Fixed)
Flap
Louver
Cooling Heating
Left/right swing
Horizontal blowing (Fixed) Slant forwardl blowing (Fixed)
Flap
Louver
Cooling Heating
Wide (Fixed)
Flap
Louver
Cooling Heating
Horizontal blowing (Fixed) Slant forwardl blowing (Fixed)
Operation mode
Room temp. – Setting temp. 2°C
Setting temp. – Room temp. 2°C
Heating
Cooling
Air flow direction contorol
2°C < Setting temp.
– Room
temp. 5°C
2°C <
Room
temp.
Setting temp. 5°C
Room temp. – Setting temp. > 5°C
Setting temp. – Room temp. > 5°C
The control in 4) continues. Control returns to the control in 2). Control returns to the control in 1).
The control in 4) continues. Control returns to the control in 2). Control returns to the control in 1).
<
=
<
=
<
=
<
=
Wide (Fixed)
Flap
Louver
Horizontal blowing (Fixed)
1)
2)
3)
4)
5)
3
4
Fan speed
During cooling and heating (Including auto cooling and heating)
setting temp.
Up/down swing
Center (Fixed)
During DRY operation
room
Room Room
room