37
ROW SEVEN (Continued)
SEQ 2 CLK OUTPUT
A clock signal based on the tempo of Sequencer 2 is available here.
CV OUTPUT: 0V to +5V
ROW EIGHT
MIDI IN INPUT
MIDI information is received via this jack using the five-pin DIN socket to
3.5mm MINI jack (MIDI Type A) adapter included with your Subharmonicon.
Specifically, Subharmonicon can receive master clock (TEMPO) information,
note data, and various CC (Control Change) messages via MIDI (see MIDI
Operations table on page 44). Clock information from a connected MIDI source
will override the internal clock setting and any connected external analog clock
source. The corresponding LED indicates that MIDI data is being received.
MIDI INPUT: MIDI data
CLOCK INPUT
A clock signal received via this jack will override the internal clock setting.
CLOCK/CV INPUT: 0V to +10V
(Rising edge = Clock Pulse)
CLOCK OUTPUT
The clock signal available from this jack reflects the current clock source,
be it internal, external, or MIDI. The clock signal is only present while the
sequencer(s) are playing and the PL AY button is lit.
CLOCK/CV OUTPUT: 0V to +10V
TRIGGER OUTPUT
Each time the VCA or VCF Envelope Generators (EG) are triggered – either by
the sequencers or by the TRIGGER button – a trigger signal will be sent from
this output.
TRIGGER/CV OUTPUT: 0V to +5V Pulse; 1 millisecond
THE PATCHBAY (Continued)

Other manuals for Moog Subharmonicon

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moog Subharmonicon and is the answer not in the manual?

Moog Subharmonicon Specifications

General IconGeneral
BrandMoog
ModelSubharmonicon
CategorySynthesizer
LanguageEnglish

Related product manuals